0-2013 GE OPTIMA 640 SPECT/CT SCANNER
Currently installed and operational. Serviced by GE. Has Xeleris 3 with Evolution. A general purpose High Performance Hybrid Spect system with a dedicated sub-system CT for High Resolution CT imaging. Xeleris 3 with EVOLUTION. Sub-system CT is used for Attenuation correction of SPECT and Anatomic localization of Radiotracer. Integrated low-dose CT with 4 slice functionality. Has 3/8” Excel crystals-Elite NXT detectors with 59 High resolution QUANTUM PMT tubes. Extra large, Rectangular UFOV. Shielded 40-620 Kev Energy. 70cm Bore and featuring Real time Automatic Body Contouring scanning in 180 degrees and 90 degrees. Real Time Status display. Real time Infrared Auto body Contouring. ECG Trigger. Has LEHR, MEGP collimators. Acquisition OPTIMA NM/CT 640 station with a 3.1 Xeleris Workstation Nuclear Medicine, PET, NM/CT and PET/CT Processing analysis and review. Evolution, Full Body with local segments for Bone, Heart, kidneys, pancreas and other anatomy selection organs |
04-21-24 |
58932 |
2013 |
Optima 640 |
SPECT/CT |
Nuclear Camera |
GE |
|
1-2016 SIEMENS SYMBIA EVO SPECT CT SCANNER
Whole Body SPECT digital dual Acquisition
Foresight Detectors
Complete with Acquisition and Processing PC’s
SYMBIA EVO VB10E software
Syngo VY21A
Windows 7 with Version 6.1
Auto QC
Collimators: Low Energy and Medium Energy
Options: NMG Auto Contour.NMG 90_76 Acquisition. NMG 180 Acquisition. NMG Whole Body. NMG WB TOMO. NMG Acquisition. NMG Display. NMG Processing. GET Worklist. NMG CEDARS QPS.NMG CEDARS QBS. NMG CEDARS General License. NMG Support. NMG PostProcessing. NMG FUSION. NMG CEDARS_Companion. CEDARSQPS. Flash 3D_General. NMG Flash3D_CARDIAC. NMG Display. NMG CT ToolBox. NMG CEDARS_PlusPack20. Processing Planar. Study_Set Up. Outer Room. NMG GURNEY. NMG General Purpose. Auto QC. PPM Display. SCATTER. CARDIAC_Scatter. General Scatter. VOLUME_SPECT. MR Support. NMG CEDARS_Suite2012.
Available Now
Located in Southeast US |
04-13-24 |
58609 |
2016 |
Symbia Evo |
SPECT/CT |
Nuclear Camera |
Siemens |
|
2-2008 GE Ventri Nuclear Camera
Dedicated Cardiac Gamma Camera with XELERIS 3. Year 2008. Dual head digital detector with Acquisition Xeleris 3. Includes ECT tool box with full cardiac software package and small organs .Compact Dual Head Gamma Camera for office or outpatient center, Cardiology and small organ use. VENTRI Acquisition HP 4300 and Processing HP Z400 PC Station and XELERIS 3 for Processing Platform. Includes 1 set of LEHR – Low Energy High Resolution collimators. Detectors: 1 ADC/PMT, 9.5mm; Crystals are 42 x 22, 28 PMT’s, 90 degree fixed angle, Xeleris 2 processing. Includes system gantry and patient table the IPS Station (Integrated Power Supply). Includes: System software for Ventri and Xeleris 3, Three LCD flat monitors, 1 bar phantom, System gantry, system stand Ventri IPS, Collimator, UPS, system Acquisition and processing station |
04-03-24 |
58933 |
2008 |
Ventri |
Nuclear Camera |
Nuclear Camera |
GE |
|
3-GE Millennium MG Nuclear Camera
Location: TX
Available now |
03-18-24 |
58884 |
- |
Millenium MG |
Nuclear Camera |
Nuclear Camera |
GE |
|
4-GE Ventri Nuclear Camera
Location: TX
Available now |
03-18-24 |
58885 |
- |
Ventri |
Nuclear Camera |
Nuclear Camera |
GE |
|
5-GE Optima NM640 SPECT/CT Scanner
Location: TX
Available now |
03-18-24 |
58888 |
- |
Optima NM640 |
SPECT/CT |
Nuclear Camera |
GE |
|
6-2005 GE MILLENIUM MG BLUE NUCLEAR CAMERA
CARDIAC and Whole Body studies / look out cancer with isotopes , Cequal with XELERIS 2.0 and 2014 Genie acquisition 4.5 with IBM series 205 server . Cardiac Ivy Trigger included.Dual Head MG Nuclear Medicine Dual-detectors Digital Gamma Camera. Has XELERIS 2.1 processing with Cardiac, Cequal Cardiac IVY monitor and whole body general studies. Three sets of COLLIMATORS: 1 set of Low Energy High Resolution (LEHR) , Medium Energy MEGP and High energy collimators |
03-18-24 |
58892 |
2005 |
MILLENIUM MG BLUE |
Nuclear Camera |
Nuclear Camera |
GE |
|
7-2012 PHILIPS CARDIO MD NUCLEAR CAMERA
Includes: Ivy Biomedical Cardiac Trigger Monitor 3000, APC Smart UPS model 2200
Location: AL |
02-18-24 |
58721 |
2012 |
Cardio MD |
Nuclear Camera |
Nuclear Camera |
Philips |
|
8-2007 GE Ventri Nuclear Camera
Ventri Model H3000YT
GE Ventri Table Model UGP001591
Ventri Integrated model
NM Xeleris 2 view
Hand Control
ECG Trigger
Some patient accessories
Windows System
Manuals
Only performs cardiac imaging
There is a clear path for removal
Ground Floor
Will need a liftgate at Origin
Installed and operational
Located in Maine
Available now |
01-14-24 |
58569 |
2007 |
Ventri |
Nuclear Camera |
Nuclear Camera |
GE |
|
9-2008 GE Infinia II Nuclear Camera
Gold sealed by GE in 2021 and was never used
Still sitting in the hospital and has never been installed
Catalog #: L3000WT
Serial number: 15777
Location: MO
Condition: Refurbished by GE and never installed |
01-08-24 |
58550 |
2008 |
Infinia II |
Nuclear Camera |
Nuclear Camera |
GE |
|
10-GE INFINIA NUCLEAR CAMERA
Dual Head,
Dual-Head Variable Angle,
Digital,
Spect Whole Body Gamma Camera,
17” Monitor,
Acquisition Genie Station and Xeleris 2,
R-Wave,
ECT Tool,
Automated,
Simultaneous Dual Collimators,
90 Degree,
3/8” Crystal Thickness,
General Tomography,
Cardiac,
Kidneys,
Renal,
Bone,
Gastro,
Pulmonary,
3D rendering,
3D filter,
59 Photomultiplier Tubes,
PMY Per Detector,
Real Time Body Contouring |
01-02-24 |
58521 |
- |
Infinia |
Nuclear Camera |
Nuclear Camera |
GE |
|
11-2008 SIEMENS SYMBIA NUCLEAR CAMERA
LOCATION: NJ |
12-20-23 |
58498 |
2008 |
Symbia |
Nuclear Camera |
Nuclear Camera |
Siemens |
|
12-(2) PHILIPS CARDIO MD NUCLEAR CAMERAS
LOCATION: NJ |
12-16-23 |
58497 |
- |
Cardio MD |
Nuclear Camera |
Nuclear Camera |
Philips |
|
13-SIEMENS SINGLE HEAD ECAM NUCLEAR CAMERA
LOCATION: NJ |
12-16-23 |
58499 |
- |
E-Cam |
Nuclear Camera |
Nuclear Camera |
Siemens |
|
14-2007 Siemens Ecam Nuclear Camera
Good operating condition
Still in use
Needs to be Deinstalled
Rig out by December 23 |
12-05-23 |
58449 |
2007 |
E-Cam |
Nuclear Camera |
Nuclear Camera |
Siemens |
|
15-2016 SIEMENS SYMBIA EVO SPECT CT SCANNER
WINDOWS 10
VB 22A SW LEVEL
SYNGO MI APPLICATIONS
CLEAN CONDITION
FULLY OPERATIONAL
AVAILABLE NOW IN SOUTHEAST |
11-16-23 |
58343 |
2016 |
SYMBIA EVO |
SPECT/CT |
Nuclear Camera |
Siemens |
|
16-Philips Cardio MD Nuclear Camera
3STD RIG OUT
AVAILABLE NOW
LOCATION: MO |
10-11-23 |
58184 |
- |
Cardio MD III |
Nuclear Camera |
Nuclear Camera |
Philips |
|
17-2013 Siemens Symbia T16 SPECT/CT Scanner
Whole Body SPECT with Fast Cardiology smart collimator. Tube is DURA 422 from year 2020 at 87,498 scan seconds. Revison Syngi VIA at Rev2007E 8.5.11.22 VA61D. Also LEHR included. Cardiac monitors. Automatic Collimator exchange |
10-07-23 |
58211 |
2013 |
Symbia T16 |
SPECT/CT |
Nuclear Camera |
Siemens |
|